No 16 high voltage insulator

Welcome to our Antique Bottle community

Be a part of something great, join today!

JerryN

Well-Known Member
Joined
Nov 22, 2012
Messages
79
Reaction score
89
Points
18
I found this large insulator in California. The only embossing is the No. 16 seen in the picture. It is threaded inside.

I have not found a similar one searching the web, though the few large ones like this suggest it is high voltage and the No. 16 is for the gauge of the wire not the CD number.

Any information about this insulator would be appreciated.

IMG-6643.jpg
IMG-6644.jpg
IMG-6645.jpg
 

digginthedog

Well-Known Member
Joined
Jun 22, 2008
Messages
160
Reaction score
1
Points
18
Location
NY
CD # 297 I think, the embossing on the front and rear skirt would be blotted out...
 

DavidW

Well-Known Member
Joined
Feb 21, 2014
Messages
303
Reaction score
251
Points
63
Location
Southern Indiana
Looking at the price guide (I don't have the latest edition) but it's definitely a CD 297. That style of insulator is listed under the "LOCKE" heading in the guide. Most of that style were made for F. M. Locke, Victor, New York - by Brookfield Glass Company. There are variations in the exact embossing seen on the insulators. Some have the "FRED M. LOCKE / VICTOR NY" on one side and "NO 16" on the other. Others have ONLY the "NO 16" lettering. Others are unmarked. Yours is a product of Brookfield Glass Company.

Just for clarification - the CD numbers assigned to insulators are never actually embossed on any insulator. The CD (Consolidated Design) numbering system to catalog and identify glass insulators, invented by Nathan R. "Woody" Woodward, has only been used by collectors, and was not used by the actual manufacturers of glass insulators.

The CD numbers were assigned decades (or even a century or more in some cases) after most of the older insulators were made. ( Just in case anyone has misunderstood and expects to see a CD number embossed into the glass on an insulator.)
 

JerryN

Well-Known Member
Joined
Nov 22, 2012
Messages
79
Reaction score
89
Points
18
Thank you for the great information! It looks like it would be hard to date as they were producing insulators from 1890 to 1912. Apparently it was rated to 15,000v
 

Bohdan

Well-Known Member
Joined
Jan 14, 2019
Messages
282
Reaction score
104
Points
43
Location
Prairies of Canada
I found this large insulator in California. The only embossing is the No. 16 seen in the picture. It is threaded inside.

I have not found a similar one searching the web, though the few large ones like this suggest it is high voltage and the No. 16 is for the gauge of the wire not the CD number.

Any information about this insulator would be appreciated.

View attachment 237398View attachment 237399View attachment 237400
I found this large insulator in California. The only embossing is the No. 16 seen in the picture. It is threaded inside.

I have not found a similar one searching the web, though the few large ones like this suggest it is high voltage and the No. 16 is for the gauge of the wire not the CD number.

Any information about this insulator would be appreciated.

View attachment 237398View attachment 237399View attachment 237400
#16 AWG is a very small wire. Some smaller lamp cords are 16ga.
 

DavidW

Well-Known Member
Joined
Feb 21, 2014
Messages
303
Reaction score
251
Points
63
Location
Southern Indiana
#16 AWG is a very small wire. Some smaller lamp cords are 16ga.
The "NO 16" in this instance is just a model number assigned by Locke to that particular style of insulator. It has nothing to do with wire sizes or diameters.
 

Bohdan

Well-Known Member
Joined
Jan 14, 2019
Messages
282
Reaction score
104
Points
43
Location
Prairies of Canada
The "NO 16" in this instance is just a model number assigned by Locke to that particular style of insulator. It has nothing to do with wire sizes or diameters.
The comment about wire gauge was in the original post (JerryN) - not mine.
 

DavidW

Well-Known Member
Joined
Feb 21, 2014
Messages
303
Reaction score
251
Points
63
Location
Southern Indiana
The comment about wire gauge was in the original post (JerryN) - not mine.
Yes, I know. My post wasn't directed at you or anyone in particular. Just posted it in case anyone at all misunderstands the purpose of the number. These threads will probably be archived and searchable via google for years to come.
 

Members online

No members online now.

Latest threads

Forum statistics

Threads
83,357
Messages
743,813
Members
24,376
Latest member
Ally_Mac
Top